Behringer U-CONTROL UCA202 User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 9
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
13 U-CONTROL UCA202 User Manual12 U-CONTROL UCA202 User Manual
FEDERAL COMMUNICATIONS
COMMISSION COMPLIANCE
INFORMATION
Responsible Party Name: MUSIC Group Services US Inc.
Address: 18912 North Creek Parkway,
Suite 200 Bothell, WA 98011,
USA
Phone/Fax No.: Phone: +1 425 672 0816
Fax: +1 425 673 7647
U-CONTROL UCA202
complies with the FCC rules as mentioned in the followingparagraph:
This equipment has been tested and found to comply with the limits for a
ClassB digital device, pursuant to part 15 of the FCC Rules. Theselimits are
designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, thereis no guarantee that interference will not occur in a
particular installation. Ifthis equipment does cause harmful interference
to radio or television reception, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the
interference by one or more of the followingmeasures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician forhelp.
This device complies with Part 15 of the FCC rules. Operation is subject to
the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
includinginterference that may cause undesired operation.
Important information:
Changes or modications to the equipment not expressly approved by
MUSICGroup can void the user’s authority to use the equipment.
U-CONTROL UCA202
USB 1.1
Connectors type A
Digital Processing
Converter 16-bit converter
Sample rate 32.0 kHz, 44.1 kHz, 48.0 kHz
System Data
Frequency response 10 Hz to 20 kHz,
±1 dB @ 44.1 kHz sample rate
10 Hz to 22 kHz,
±1 dB @ 48.0 kHz sample rate
THD 0.05% typ. @ -10 dBV, 1 kHz
Crosstalk -77 dB @ 0 dBV, 1 kHz
Signal-to-noise ratio A/D 89 dB typ. @
1 kHz, A-weighted
D/A 96 dB typ. @
1 kHz, A-weighted
Power Supply
USB connection 5 V , 100 mA max.
Dimensions / Weight
Dimensions (H x W x D) approx. 0.87 x 2.36 x 3.46"
approx. 22 x 60 x 88 mm
Weight approx. 0.22 lbs / 0.10 kg
BEHRINGER always takes great care to ensure the highest standard of quality. Any modifications
which may be necessary will be made without prior notification. Specifications and appearance
of the equipment can therefore differ from the details or illustrations shown.